2018-12-29 21:03:26 +03:00

36 lines
1000 B
Markdown

Self-made chiller control system
UART: 115200N1, not more than 100ms between data bytes in command
To turn ON human terminal (without timeout) send "####"
Protocol: [ command line ]
'[' clears earlier input
'\n', '\r', ' ', '\t' are ignored
All messages are asynchroneous!
Commands:
Ax - turn on(x=1)/off(x=0) external alarm or check its value
Cx - set cooler PWM to x
d - (only when EBUG defined) go into debug commands
F - get flow sensor rate for 5s period
Hx - set heater PWM to x
L - check water level sensor value
Px - set pump PWM to x
R - reset MCU
Tx - get NTC temperature for channel x
t - get MCU temperature
V - get Vdd value *100V
Debugging commands:
A - show raw ADC value (next letter is index, 0..5)
F - get flow_cntr value & PB state
T - show raw T values
w - test watchdog
Messages:
MCUTEMP10=x - mcu temperature * 10 (degrC)
SOFTRESET=1 - software reset occured (msg @ start)
VDD100=x - Vdd*100 (V)
WDGRESET=1 - watchdog reset occured (msg @ start)