Management of two stepper motors
|
|
================================
|
|
|
|
Based on STM32F030F4P6
|
|
|
|
## Pinout
|
|
|
|
|Pin | Type | Role |
|
|
|:---|:----:|:------------------------|
|
|
|PA0 | AIN | Steppers current |
|
|
|PA1 | AIN | Input voltage 12V |
|
|
|PA2 | AIN | EndSwitch1 of motor0 |
|
|
|PA3 | AIN | EndSwitch0 of motor0 |
|
|
|PA4 | PUPD | Tim14Ch1 - motor0 steps |
|
|
|PA5 | PUPD | Motor1 enable |
|
|
|PA6 | PUPD | Tim3Ch1 - motor1 steps |
|
|
|PA7 | PUPD | Motor1 direction |
|
|
|PA9 | OD | USART1 Tx |
|
|
|PA10| FIN | USART1 Rx |
|
|
|PA13| FINPU| EndSwitch0 of motor1 |
|
|
|PA14| FINPU| EndSwitch1 of motor1 |
|
|
|PB1 | PUPD | Turn off current sensor |
|
|
|PF0 | PUPD | Motor0 enable |
|
|
|PF1 | PUPD | Motor0 direction |
|
|
|
|
## Protocol
|
|
|
|
Any command have format "# CMD", where # is device ID (the_conf.devID) or "-1" if there's
|
|
only one device at the bus. After it can be any number of spaces and command symbols.
|
|
If the command recognized and it's right, `ALL OK` would be returnded. If the command is bad, answer
|
|
`BADCMD`. Error in command sintax: `ERR`. If the answer would take more than one line it would
|
|
be ends by `DATAEND`.
|
|
|
|
### First symbol of commands
|
|
|
|
* (nothing except spaces) - *ping* command, device with given ID answers: `ALIVE`
|
|
* **G** - one of the *Getters* (depending on next text)
|
|
* **M** - motors' manipulation
|
|
* **R** - make *MCU software reboot* (next `status` getter will return `SOFTRESET=1`)
|
|
* **S** - one of the *Setters*
|
|
* **W** - *write flash* command, use it to save new configuration data
|
|
|
|
All wrong commands will return `BADCMD`, commands with bad format or wrong number return `ERR`.
|
|
Commands with lot of output ends with `DATAEND`. Some commands (like flash write) will return
|
|
just `ALL OK` if succeed.
|
|
|
|
### Getters
|
|
|
|
Getters returning more than one field ends with `DATAEND` meaning that's all data.
|
|
|
|
* **A** - get *ADC value*
|
|
* **D** - Vdd value (*100 Volts), e.g. `VDD=330`
|
|
* **I** - total motors' current (*100 Amperes), e.g. `IMOT=123`
|
|
* **M** - motor's voltage (*100 Volts), e.g. `VMOT=1193`
|
|
* **C** - get *current configuration*, e.g.
|
|
|
|
```
|
|
CONFSZ=36
|
|
DEVID=0
|
|
V12NUM=1
|
|
V12DEN=10
|
|
I12NUM=1
|
|
I12DEN=1
|
|
V33NUM=1
|
|
V33DEN=1
|
|
ESWTHR=150
|
|
MOT0SPD=60
|
|
MOT1SPD=60
|
|
USARTSPD=115200
|
|
REVERSE0=0
|
|
REVERSE1=0
|
|
MAXSTEPS0=0
|
|
MAXSTEPS1=0
|
|
DATAEND
|
|
```
|
|
|
|
All variables here are fields of `user_conf` struct.
|
|
|
|
|
|
* **R** - get *raw ADC* values:
|
|
* 0 - Steppers current
|
|
* 1 - Input voltage 12V
|
|
* 2 - EndSwitch2 of motor1
|
|
* 3 - EndSwitch1 of motor1
|
|
* 4 - inner temperature
|
|
* 5 - vref
|
|
|
|
E.g.:
|
|
|
|
```
|
|
ADC[0]=4095
|
|
ADC[1]=2340
|
|
ADC[2]=4095
|
|
ADC[3]=4087
|
|
ADC[4]=1665
|
|
ADC[5]=1532
|
|
DATAEND
|
|
```
|
|
|
|
|
|
|
|
* **S** - get *motors' status*, e.g.
|
|
|
|
```
|
|
SOFTRESET=1
|
|
MOTOR0=STOP
|
|
POS0=-1
|
|
ESW00=ERR
|
|
ESW01=BTN
|
|
MOTOR1=STOP
|
|
POS1=-1
|
|
ESW10=HALL
|
|
ESW11=HALL
|
|
|
|
```
|
|
|
|
* **T** - get *MCU temperature*, e.g. `TEMP=365`
|
|
|
|
|
|
### Motors' manipulation
|
|
Next char should be '0' or '1' --- motor's number. If wrong, `Num>1` answer would be returned.
|
|
There's only two commands in this section:
|
|
|
|
* **Mnum** - move motor to *num* steps. Errors:
|
|
* **BadSteps** - *num* isn't a number
|
|
* **IsMoving** - motor is still moving, stop it before
|
|
* **OnEndSwitch** - the motor is on end-switch limiting moving in given direction
|
|
* **ZeroMove** - user wants to move for 0 steps
|
|
* **TooBigNumber** - amount of steps is greater than `MAXSTEPSx`
|
|
* **S** - stop motor
|
|
|
|
|
|
### Setters
|
|
Change of any setter takes place in MCU RAM immediately. To store them permanently run
|
|
*write flash* command.
|
|
|
|
* **C#num** - set current *speed* to *num* for motor #
|
|
* **D num** - set *denominator* to number *num*
|
|
* **E num** - set *numerator*
|
|
* **I num** - set *device ID*
|
|
* **M#num** - set maxsteps (*num* is 1..65535) for motor `#`
|
|
* **P num** - properties of internal pullup (0 - disabled, other or without `num` - enabled)
|
|
* **R#num** - set reverse for motor # (*num* == 0 turns reverse off, *num* == 1 turns it on)
|
|
* **S#num** - set *speed* (`motspd`) to *num* for motor #
|
|
* **T num** - set *end-switches threshold* (in ADU, near 0 for Hall switch, 2048 for user button
|
|
and 4096 for released state)
|
|
* **U num** - set *USART speed* to *num* bits per second
|
|
|
|
### Motor speed setters
|
|
To set motor speed to **N** steps per second, give command `C` or `S` with argument equal to
|
|
3000/N. E.g. to set current speed for DevID=0, motor0 to 50 steps per second give command `0SC050`.
|
|
|
|
### Denominator and numerator setters
|
|
Have naxt letter similar to ADC getter (**D** - Vdd, **I** - motors' I, or **M** - motors' U).
|
|
The value of numerator shouldn't be very large as uint32_t used in multiplications.
|
|
|
|
### Device ID setter
|
|
After this command device will immediately change it's ID, if you "lost" device after this
|
|
procedure you should reboot it or (if there's only one device on the bus) call it by "universal ID"
|
|
(-1).
|
|
|
|
### USART speed setter
|
|
The USART speed will be changed after next reset (e.g. by *MCU software reboot* command), so it
|
|
don't work without storing in the flash. Check it twice before writing as wrong numbers can make device
|
|
lost until next re-flashing.
|