add report (russian)

This commit is contained in:
eddyem
2018-10-01 08:52:02 +03:00
parent 146587f6b6
commit 3b8755fb6c
22 changed files with 556 additions and 3 deletions

View File

@@ -43,9 +43,20 @@ Variable data length: from 1 to 7 bytes.
First byte of every sequence is command mark (0xA5) or data mark (0x5A).
Commands:
- CMD_PING - send from master to receive answer in data packet if target alive.
- CMD_START_MEASUREMENT - start single temperature measurement.
- CMD_SENSORS_STATE - state of sensors.
- CMD_PING request for PONG cmd
- CMD_START_MEASUREMENT start single temperature measurement
- CMD_SENSORS_STATE get sensors state
- CMD_START_SCAN run scan mode
- CMD_STOP_SCAN stop scan mode
- CMD_SENSORS_OFF turn off power of sensors
- CMD_LOWEST_SPEED lowest I2C speed
- CMD_LOW_SPEED low I2C speed (10kHz)
- CMD_HIGH_SPEED high I2C speed (100kHz)
- CMD_REINIT_I2C reinit I2C with current speed
Dummy commands for test purposes:
- CMD_DUMMY0 = 0xDA,
- CMD_DUMMY1 = 0xAD
Data format:
- 1 byte - Controller number