2023-09-22 16:21:05 +03:00
..
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00
2023-09-22 16:21:05 +03:00

Shutter control

Works with bi-stable shutter. You can find the device in /dev/shutterX (symlink to /dev/ttyUSBX).

Pinout

PB0 (pullup in) - hall (or reed switch) sensor input (active low) - opened shutter detector

PB11 (pullup in) - CCD or button input: open at low signal, close at high

PA3 (ADC in) - shutter voltage (approx 1/12 U)

PA5 (PP out) - TLE5205 IN2

PA6 (PP out) - TLE5205 IN1

PA7 (pullup in) - TLE5205 FB

PA10 (PP out) - USB pullup (active low)

PA11, PA12 - USB

PA13, PA14 - SWD

Commands

  • '0' - shutter CLO
  • '1' - shutter OPE
  • '2' - shutter HIZ
  • 'A' - get raw ADC values
  • 'C' - close shutter / abort exposition
  • 'E n' - expose for n milliseconds
  • 'O' - open shutter
  • 'R' - software reset
  • 'S' - get shutter state; also hall and ccd inputs state (1 - active)
  • 't' - get MCU temperature (/10degC)
  • 'T' - get Tms
  • 'v' - get Vdd (/100V)
  • 'V' - get shutter voltage (/100V)
  • 'W' - test watchdog

If you will enter wrong long message, will receive its echo back. Any wrong short command will show help list.

Shutter control

Commands '0', '1' and '2' should be used only for debugging purposes. To open/close shutter use only 'O', 'C' and 'E' commands.

When opening or closing shutter you will first receive an answer: OK if command could be done or ERR if there's insufficient voltage on capacitor or shutter is absent. After opened the message shutter=opened will appear. After closing you will receive messages exptime=xxx (when xxx is approx. exp. time in milliseconds) and shutter=closed.

Command 'E' could return OK, ERR or ERRNUM/I32OVERFLOW in wrong number format (number could be decimal, 0x.. - hexadecimal, b.. - binary or 0.. - octal).

When exposition starts you will receive message OK and shutter=opened. After its end you'll got exptime=..., shutter=closed. If shutter can't be closed, you will give a lots of "exp=cantclose" and different error messages until problem be solved. To stop this error messages give command 'O'.

Different commands

  • 'A' will show raw values for all ADC channels: 0. - capacitor voltage, 1 - MCU temperature, 2 - MCU Vdd. You will give messages like adcX=val.

  • 't' - mcut=val, where val = T*10 degrC.

  • 'T' - tms=val, val in ms.

  • 'v' - vdd=val, val in V*100

  • 'V' - "voltage=val", val in V*100

  • 'S' - several answers:

    • shutter=: closed, opened, error, process, wait or exposing - shutter state
    • exptime=... (only when shutter is opened) - show time since opening
    • regstate=: open, close, off or hiZ - TLE5205 outputs state
    • fbstate=: 0 or 1 - TLE5205 FB out state (1 - error)
    • hall=: 0 or 1 - 1 for opened shutter, 0 for closed
    • ccd=: 0 or 1 - 1 for active (closed contacts) state of "CCD" input