1. Overview

The product is a two‑part system for controlling BTA dome driven by a set of AC motors with ESQ‑770 frequency converters and a Modbus I/O board (relays, discrete inputs, ADC):

  • dome_server — runs on the machine connected to the RS‑485 bus. It talks Modbus RTU to the frequency converters and the I/O board, and serves an SSL/TLS socket with a simple ASCII line protocol.
  • dome_client — connects to the server, keeps the dome shared‑memory block (bta_shdata) up to date, drives the motors according to commands from the higher‑level control system, and can also be used interactively in terminal mode.

Both binaries share the same argument parser, daemonization code, and SSL socket layer. The client and server are mutually exclusive builds of the same sources (-DCLIENT / -DSERVER).

Key properties:

Property Value
Transport TCP + TLS (min. TLS 1.2), mutual authentication
Default port 4444
Protocol newline‑terminated ASCII, key (getter) or key=value (setter)
Motor bus Modbus RTU over RS‑485, 10 drives, IDs 1…10
Max SSL clients 10 (BACKLOG)
Network timeout 1 s (configurable)

2. Repository layout

File Purpose
main.c Entry point: init, parse args, start daemon
cmdlnopts.c/.h Command line / config file parsing, global G structure
daemon.c/.h Daemonization, PID file, signal handling, child supervision
sslsock.c/.h SSL context creation, socket open/connect, read_string()
client.c/.h Client main loop, terminal mode, motor polling, speed control
server.c/.h Server poll loop, connection handling, command dispatch, handlers
motors.c/.h Modbus motor control, state cache, emulation, logging
io.c/.h Modbus I/O board: relays, inputs, ADC, safety interlock logic
esq770.h ESQ‑770 register map, command/status codes, unit conversions
handlers_list.h X‑macro list of protocol commands (must stay sorted!)
Makefile Build rules for dome_client / dome_server
bta_shdata.c/.h shared memory with the dome control subsystem

3. Building

make            # release build (adds -flto); the default target
make debug      # debug build (-Werror, -DEBUG)
make clean      # remove object dirs and build.target
make xclean     # clean + remove binaries

Dependencies:

  • libusefull_macros (logging, CLI parsing, config files, time helpers)
  • OpenSSL (libssl, libcrypto)
  • libmodbus (server only)
  • libcrypt (client only)

Build details:

  • The selected target is stored in build.target; if it contains DEBUG, a plain make also builds the debug variant. Use make DEF=... to append extra defines.
  • Binaries are dome_server and dome_client; objects go to mkserver/ and mkclient/ respectively.
  • The debug build passes -DEBUG, which GCC interprets as -D EBUG, i.e. it defines the EBUG macro used throughout the code for verbose diagnostic printing.

4. Architecture

 higher-level control (GUI / SHM)          operator (terminal mode)
            |                                       |
       bta_shdata  <--- dome_client ---TLS---> dome_server
                                                   |
                                        Modbus RTU (RS-485)
                                       /                    \
                             ESQ-770 drives 1..10       I/O board
                             (motors)                   (relays/inputs/ADC)
  • The client reads the shared memory block sdat (dome speed command, lock flags, telescope position, server PID, etc.), polls motor state from the server in a round‑robin fashion, writes averaged state and SEW data back into SHM, and sends status messages to the GUI via SendMessage().
  • The server is a poll‑driven event loop: every iteration it advances the motor state machine, processes the I/O board, and serves any pending SSL traffic.
  • Both sides are non‑blocking; the server uses poll() with an 1 ms timeout, the client sleeps ~100 ms per cycle.

5. SSL layer (sslsock.c)

open_socket():

  1. Initializes the OpenSSL library and creates a context (TLS_server_method() / TLS_client_method()).
  2. Requires TLS ≥ 1.2.
  3. Loads the CA file (-a, default ca_cert.pem); on the server side the CA list is also loaded so the client certificate can be requested.
  4. Loads the certificate (-c) and private key (-k), checks key/cert match.
  5. Verification:
  • Server: SSL_VERIFY_PEER | SSL_VERIFY_FAIL_IF_NO_PEER_CERT — a valid client certificate signed by the CA is mandatory.
  • Client: SSL_VERIFY_PEER.
  • Verification depth is limited to 1 (only certificates signed directly by the CA are accepted).
  1. Opens the socket:
  • Server: bind() to INADDR_ANY:<port> with SO_REUSEADDR, then listen(BACKLOG).
  • Client: resolves --server via gethostbyname() and connect()s.

read_string(ssl, buf, l) reads one \n‑terminated line:

  • Uses SSL_peek() to locate the newline without consuming data.
  • If the buffer fills up before a newline, the pending data is discarded (SSL_read of l bytes) and 0 is returned.
  • Returns the number of bytes read (the trailing \n is replaced by \0), 0 if nothing is available or the line is incomplete, and -1 on disconnect/error. SSL_ERROR_WANT_READ/WRITE are treated as “nothing yet”.

6. Protocol

Text, one message per line, \n terminator.

6.1 Message forms

Form Meaning Reply
name getter name=value
name=value setter OK, BADVAL, BADKEY or FAIL
help list commands one command: description line per command
empty line / comment ignored (no reply)

The client side (send_motor_command()) distinguishes getters from setters by the presence of =, and treats the four uppercase tokens above as setter results. In practice only motnum, motstatus, motspeed, motcurrent, speed, stop, nmotors, forbidden are used by the client.

6.2 Result codes

Token Enum Meaning
OK RESULT_OK setter executed
BADVAL RESULT_BADVAL malformed or out‑of‑range argument
BADKEY RESULT_BADKEY unknown command
FAIL RESULT_FAIL command failed (e.g. motors not running)
(no token) RESULT_SILENCE internal: getter answer is sent as key=value or no answer at all

7. Command reference

All commands are defined once in handlers_list.h and expanded into the server’s dispatch table. The list must be kept in alphabetical order — the server looks commands up with a binary search (search_handler()).

Command Access Argument / answer Description
adc=N get N → value Read ADC channel N (0…7)
forbidden get/set 0/1 Setter: 1 forbids dome operations (blocks motors), 0 permits. Getter: state of the RELAY_BLOCK_MOTORS relay (1 = forbidden)
inputs get decimal mask State of the 16 discrete inputs
logprefix get/set string ≤ 31 chars Prefix of motor log files (<prefix>_NN.log)
motcurrent get amps Current of the active motor
motnum get/set 0…9 Number of the motor used by status/current/speed getters
motspeed get rev/min Speed of the active motor
motstatus get 0…3 Status of the active motor (see below)
nmotors get count Number of motors whose status is not OFF
relayon get/set N / mask Setter: turn relay N on. Getter: full relay state mask
relayoff get/set N / mask Setter: turn relay N off. Getter: full relay state mask
relayset get/set mask Setter: set/reset all relays at once by bit mask. Getter: state mask
speed get/set rev/min Setter: speed setpoint, sign selects direction, 0 stops. Getter: current setpoint
startlog action — Open per‑motor log files
stop action — Stop all motors
stoplog action — Close log files

Motor status values (motors.h)

Value Name Meaning
0 MOT_OFF no answer / disabled
1 MOT_SLEEP stopped but ready
2 MOT_RUN rotating
3 MOT_ERROR drive fault

nmotors counts all motors whose status differs from MOT_OFF.

Relay / input bit masks (io.h)

Inputs (16 bits):

Bit Macro Meaning
0 INP_FLOOR1 man on floor 1
1 INP_FLOOR2 man on floor 2
2 INP_DOOR_OPENED door is open
3 INP_OPEN_DOOR “open door” request
4 INP_TEL_AT_NEST telescope is at the “nest”

Relays (16 bits, only some are populated):

Number Macro Meaning
1 RELAY_OPEN_DOOR open the door
2 RELAY_BLOCK_DOOR block the door
3 RELAY_LIGHT turn on light
4 RELAY_POWER turn on power socket
5 RELAY_BLOCK_MOTORS block (inhibit) the motors
10 RELAY_DOOR_UNLOCKED door is unlocked (turn on light)

8. Server

8.1 Startup

main() → sl_init() → parse_args() → start_daemon() → open_socket() → serverproc().

start_daemon() (in daemon.c) validates the port (1024…65535) and that certificate/key files can be opened; optionally opens the log file; installs signal handlers; checks for an already‑running instance via the PID file; then daemonizes and runs the supervision loop:

  • The master forks a child, waits for it, logs the child’s lifetime, and respawns after 5 s. Logging is throttled if children die faster than 30 s.
  • The child sets PR_SET_PDEATHSIG = SIGTERM (it is killed when the master dies), sets isrunning = TRUE and runs the main loop.

Signals: SIGTERM, SIGINT, SIGQUIT set isrunning = FALSE and exit (after removing the PID file); SIGTSTP and SIGHUP are ignored.

8.2 Main loop (serverproc())

  1. motors_process() — advance the motor state machine (one motor per call plus queued commands).
  2. io_process() — read inputs/relays/ADC from the I/O board and apply the safety logic.
  3. poll(..., 1 ms).
  4. On the listening socket: accept4(..., SOCK_NONBLOCK), then SSL_new() + timeout‑protected SSL_accept() (bounded by --timeout). On failure the client is sent an error and disconnected. Up to BACKLOG (10) clients are served.
  5. For each readable client: handle_connection() — read one line, parse key[=value], dispatch to the handler, write the reply. On disconnect the last poll entry is moved into the freed slot.

On exit the server stops all motors and closes the Modbus connection.

8.3 Motor control (motors.c)

  • One Modbus RTU context for the whole process, shared with io.c via io_set_ctx().
  • Shared‑memory‑like state in the server: motstates[10], n_working_motors, speed/current setpoints, and a bit‑flag word (stop, change_speed, change_current), all protected by statemutex.
  • Setter path (motors_set_speedsetpoint(), motors_set_curntsetpoint(), motors_stop()) only sets flags; the actual bus traffic happens in motors_process_m():
    • Commands are sent to the broadcast slave address 0 (modbus_set_slave(ctx, 0)) without checking the return code (what's impossible in broadcast mode).
    • stop → CMD_STOP on REG_CMD, setpoint zeroed.
    • Speed change: if |speed| < SPEED_TOLERANCE → CMD_STOP; otherwise write CMD_FORWARD/CMD_REVERSE to REG_CMD and REVMIN2FREQ(|speed|) to REG_FREQ_SET.
    • Setting a speed requires n_working_motors ≥ MIN_WORKING_MOTORS (1); otherwise RESULT_FAIL.
    • |speed| > MAX_SPEED (655 rev/min) → RESULT_BADVAL.
    • Changing the current setpoint is currently a stub (change_current is cleared without bus traffic).
  • Polling path: each call selects one slave MOTOR_ID(curN) = curN+1 and reads REG_STATUS_MAIN, REG_STATUS_EXT, REG_OUTPUT_FREQ, REG_OUTPUT_CURRENT; converts to rev/min and amperes; maps statuses:
    • STATUS_CW, STATUS_CCW → MOT_RUN
    • STATUS_STOP → MOT_SLEEP
    • anything else → MOT_ERROR
    • STATUS_READY_MASK absent in the extended status → forced MOT_ERROR; an attempt is made to reset the fault with CMD_RESET_FAULT.
    • After MAX_ERRORS (5) consecutive bus errors the motor is marked MOT_OFF.
  • count_motors() recomputes n_working_motors after each full sweep.

8.4 Motor logging

start_log() opens <mldir>/<prefix>_NN.log (append mode) for each motor (default prefix motor, default directory /tmp). Each poll writes time<TAB>speed<TAB>current, but only while the motor is MOT_RUN. stop_log() closes them. Prefixes are validated (set_logfile_prefix() rejects /, %, control characters and non‑ASCII, and limits length to 31).

8.5 Emulation mode

With --emulation the server skips the serial port and uses motors_open_e() / motors_process_e():

  • All motors start in MOT_SLEEP; n_working_motors = 10.
  • Speed ramps linearly toward the setpoint with EMUL_ACCEL (10000 min⁻²); current equals the current setpoint while accelerating and 0.6 × setpoint when at speed.

8.6 I/O board (io.c)

  • The board is addressed by G.io_ID; if it is < 1 or the Modbus context is missing, io_process() does nothing.
  • Each pass reads 16 inputs, 16 relay outputs and 8 ADC registers, updates the cached state under a mutex, then runs the interlock logic.
  • Inputs → relays (chk_inputs()):
    • Any of FLOOR1, FLOOR2, DOOR_OPENED → door unblocked and unlocked, motors blocked, light on.
    • TEL_AT_NEST → door unblocked/unlocked, and if OPEN_DOOR is asserted the door is opened and the motors blocked.
    • Otherwise the door is blocked and locked; if somebody is on the nest without the telescope, the open‑door request is honoured.
  • Relays → relays (chk_relays()): motors blocked ⇒ light on, otherwise off. Pending user requests (OnFlags/OffFlags) are applied and cleared.
  • Public API: io_read_inputs(), io_read_relays(), io_read_adc(), io_relay_on(), io_relay_off(), io_set_relays().
  • At server start, io_set_relays(0) turns everything off and then RELAY_BLOCK_MOTORS is switched on (inhibit by default).

9. Client

9.1 Connection setup

clientproc() / terminal() create an SSL connection (openConn()), make the socket non‑blocking, attach the shared memory block (get_shm_block(&sdat, ClientSide) — may fail if the SHM block is not created by the higher‑level system), the command queues (mcmd, ocmd, ucmd), and publish DomeSEW_N = MOTORS_AMOUNT.

9.2 Background (daemon) mode — clientproc()

Every ~100 ms:

  1. process_system(ssl):
  • SHM watchdog: if M_time lags more than T_sync_lost behind wall time, or check_shm_block() fails, the client tolerates 9 failures and exits on the 10th.
  • Model mode: if the SHM reports UseModel == FullModel, the client logs a warning once, sends an emergency stop, and suspends control until the model mode ends.
  • Server liveness (unless --emulation): kill(ServPID, 0); two consecutive failures terminate the client.
  • Motor polling: round‑robin over 10 motors with 4 commands each — motnum=N, motstatus, motspeed, motcurrent. The active‑motor data feed the SEWD variables (statusSEWD, vel_SEWD, currentSEWD) for indexSEWD.
  • After the full sweep, the common state is computed: status = maximum over motors, speed/current = mean over MOT_RUN motors. Transitions between “all off” and “any running” generate MesgFault/MesgInfor messages to the GUI; an unresponsive motor in error state generates MesgWarn.
  • chk_dome_speed(): translates the SHM Dome_Speed state (D_Off, D_Lplus/Lminus, D_Mplus/Mminus, D_Hplus/Hminus) into ±LSpeed/MSpeed/HSpeed (±71/350/610 rev/min). The command is (re)sent every speedchk_interval seconds until the measured speed is within SPEED_TOLERANCE of the setpoint. D_Locked forces a stop.
  1. Drain and log any unsolicited data from the server.

On exit: stop_all() sends stop up to 5 times (100 ms apart); if all attempts fail, an error is logged; otherwise Dome_Speed is reset.

9.3 Terminal mode — terminal()

Enabled by -T. Before daemonizing (so it works without detaching), the client offers a raw line pipe:

  • > prompt; each line read from stdin is written to the SSL connection.
  • Every reply line is printed as < reply.
  • Ctrl‑D or a write error ends the session.

The shared memory block and automatic motor polling are not used in this mode.

10. ESQ‑770 frequency converter interface (esq770.h)

Register Address Access Contents
REG_CMD 0x2000 RW Command
REG_FREQ_SET 0x3000 RW Frequency setpoint (0.01 Hz)
REG_TORQUE_LIMIT 0x3006 RW Torque limit
REG_BRAKE_TORQUE_LIMIT 0x3007 RW Brake torque limit
REG_STATUS_MAIN 0x6000 R Main status
REG_STATUS_EXT 0x6001 R Extended status
REG_OUTPUT_FREQ 0xA201 R Output frequency × 100
REG_OUTPUT_CURRENT 0xA204 R Output current × 10
REG_MOTOR_SPEED 0xA205 R Speed (depends on settings)

Commands (REG_CMD): CMD_FORWARD = 1, CMD_REVERSE = 2, CMD_STOP = 5, CMD_FAST_STOP = 6, CMD_RESET_FAULT = 7.

Main status (REG_STATUS_MAIN): STATUS_CW = 1, STATUS_CCW = 2, STATUS_STOP = 3, STATUS_ERR = 4, STATUS_LOW_V = 5. Extended status bit STATUS_READY_MASK = 0x01.

Conversions (4‑pole motor, 100× scale):

REVMIN2FREQ(r) = (uint16_t)(100. * r / 15.)   /* rev/min → register */
FREQ2REVMIN(f) = (f * 15.) / 100.             /* register → rev/min */
current[A]     = register / CURRENT_SCALE     /* CURRENT_SCALE = 10 */

Because the frequency register is 16‑bit, the maximum representable speed is 655.35 rev/min (MAX_SPEED = 655).

11. Command line options

Defined in cmdlnopts.c; configuration files (-C) use the same names and take precedence over the command line. -v, -v2, -v3 raise the log level to MSG, DBG and ANY respectively (default WARN).

Common

Option Argument Default Description
-h, --help — — show help
-l, --logfile file — write logs to this file
-P, --pidfile file /tmp/domeserver.pid / /tmp/domeclt.pid PID file
-c, --certificate file server_cert.pem / client_cert.pem SSL certificate
-k, --key file server_key.pem / client_key.pem SSL private key
-p, --port string 4444 TCP port
-v, --verbose int (optional) 0 verbosity level
-a, --ca file ca_cert.pem CA certificate
-t, --timeout double 1 s network timeout (accept, command reply)
-C, --conffile file — configuration file

The certificate and private key files must have absolute path as are opened after daemonisation and chroot('/').

Server only

Option Argument Default Description
-e, --emulation — off emulation mode (no hardware)
-d, --serialdev file — RS‑485 device path (absolute)
-s, --serialspeed int — serial port speed
-D, --mldir dir /tmp directory for motor log files (absolute)
-i, --ioid int −1 Modbus ID of the I/O board (disabled if < 1)

Client only

Option Argument Default Description
-M, --mottmout double 10 s interval for re‑sending the speed command until it is reached
-s, --server host — (required) server name or IP
-L, --lostsync double 5 s shared‑memory “lost synchronization” timeout
-e, --emulation — off run even if the SHM reports emulation mode
-T, --terminal — off interactive terminal mode

Note that -s has different meanings in the server (serialspeed) and client (server) builds — the option tables are compiled conditionally.

12. Tuning constants

motors.h / esq770.h:

Constant Value Meaning
MOTORS_AMOUNT 10 number of drives
START_ID / MOTOR_ID(n) 1 / n+1 Modbus slave addresses
MIN_WORKING_MOTORS 1 minimum motors to allow a speed setpoint
MAX_ERRORS 5 consecutive bus errors before a motor is MOT_OFF
MAX_SPEED 655 rev/min
SPEED_TOLERANCE 0.01 rev/min
MAX_CURRENT / DEFAULT_CURRENT 15 / 10 A
LSpeed / MSpeed / HSpeed 71 / 350 / 610 rev/min presets
MODBUS_RESPONCE_TIMEOUT 100000 µs
EMUL_ACCEL 10000 min⁻²
BACKLOG 10 max simultaneous SSL clients
IOBUF_LEN / SL_VAL_LEN / SL_KEY_LEN 256 / (external) protocol buffer sizes

13. Client ↔ shared memory integration

The client depends on the bta_shdata.[ch] module that provides:

  • sdat — the shared struct (mode, atflag, Dome_Speed, D_Locked, DomeSEW_N, indexSEWD, statusSEWD, vel_SEWD, currentSEWD, speedSEWD, M_time, UseModel, ServPID, …);
  • command queues mcmd, ocmd, ucmd (motor / observer / user commands);
  • helpers get_shm_block(), check_shm_block(), get_cmd_queue();
  • SendMessage() with MesgWarn, MesgFault, MesgInfor message classes for the GUI.

The client writes the shared block (mode |= 0200, i.e. write access, atflag = 0) and publishes DomeSEW_N. If the block cannot be attached, the client logs the error and aborts.

14. Notes and caveats

  • Command order is significant. handlers_list.h must remain alphabetically sorted; the server uses binary search over the expanded table.
  • The EBUG macro is produced by the Makefile’s -DEBUG flag (GCC parses it as -D EBUG). Debug builds therefore enable extra printf traces in io.c, motors.c, etc., and disable daemonization (#ifndef EBUG around sl_daemonize()), which is handy for running under a debugger.
  • Setters vs. getters are distinguished purely by the presence of =. startlog, stop, stoplog are actions; any =value they receive is ignored.
  • The relay getters of relayon, relayoff, relayset are identical (they all return the full relay mask); the setter forms differ.
  • The server broadcasts motion commands (slave 0) and therefore does not verify their execution; confirmation happens only indirectly through the client’s periodic speed polling and re‑sending.
  • Motor speed commands are accepted only when at least MIN_WORKING_MOTORS drives are alive; otherwise RESULT_FAIL is returned.
  • read_string() silently drops a line that does not fit into the buffer; keep IOBUF_LEN in mind for custom clients.
  • The I/O board’s safety logic runs before the relay state is refreshed, so user relay requests issued in the same iteration may be overwritten by the interlock rules on the next pass.

15. License

This repository is provided under the GNU General Public License v3 or later. Full text of the GPLv3 is available at https://www.gnu.org/licenses/gpl-3.0.html.